Glass Canada - February 2017

You Bet Your Glass

Frank Fulton 2017-02-02 02:36:57

Requirement and reaction

You probably remember all the kerfuffle brought on by mainstream media a few years ago over the epidemic of shattered glass falling from high rise buildings onto the heads of unsuspecting pedestrians. People were afraid to walk outside, Toronto politicians panicked and an emergency panel was assembled to find ways to combat this terrifying phenomenon. The panel determined without a doubt that the culprits responsible for the spontaneous breakage were nickel sulphide (NiS) inclusions, microscopic impurities found in glass comprised of nickel and sulphur that shrink when glass is being tempered then expand unexpectedly in random situations later on causing the tempered lite to shatter. The panel made their recommendations and based on those the Ontario government issued a hasty edit to SB-13 that went into effect on July 1, 2012. At about the same time the Canadian Standards Association (CSA) was tasked with developing a national standard to be incorporated into the National Building Code of Canada (NBCC) and provincial codes.

The CSA just released the “A500-16 Building Guards” standard and compliance will soon be mandatory. This standard specifies requirements for the materials, design, construction, testing and performance of building guards that act as protective barriers to prevent accidental falls from one level to another, and includes walls that serve this purpose. Considering the public safety aspect of guards, it’s amazing that there hasn’t been a national code to govern them until now.

Similar to windows and curtainwall, guards must now be designed and tested to withstand the wind loads they will be subjected to, as well as strength, anchorage and fasteners, component spacing and deflection and impact. The type of glass that can be used as a guard infill is determined by the proximity of the plane of glass to the floor edge. Laminated glass can be used in all conditions. Heat soaked tempered glass can only be used when the glass is 50 millimeters or more inboard of the floor edge and monolithic tempered glass can only be used when the glass is 150 mm or more inboard of the floor edge. That may sound simple enough but when combined with the new impact-testing criteria that requires the glass to remain in place after being hit with a 100-pound bag of lead shot, laminated glass with a flexible interlayer may not pass muster in certain conditions or systems. Determining the right infill product for the job will be a much tougher prospect requiring pre-project engineering and a lot of up-front due diligence by all parties to a contract.

As head of the Façade Engineering Group of Exp Services and a member of the A500 standard technical committee, Greg Hildebrand has seen his share of issues with glass in guards and railings. He notes “the problem isn’t limited to spontaneous glass breakage but with the railing systems themselves,” hence the need for a standard that takes the entire system into account. “Glass is ‘walking’ out of glazing channels, die-cast shoes holding the posts are breaking and intact lites of glass have fallen out of railings to the ground after being subjected to the dynamic forces of the wind.”

Sergei Mihhailenko, president of Mihko Engineering, is not particularly happy with the new standard, arguing that many facets of the standard are already addressed in current building codes. He also considers that our engineering community is more that qualified to assess the strength of the materials that combine to make up a guard and that all of the testing specified in the new standard is unnecessary. Hildebrand counters that “Yes, it’s true that engineers can assess the strength of all of the materials. However, the guard assemblies can be quite complex and it is practically impossible for an engineer to assess how all of the components will work together when impacted.” Both engineers are in agreement that every guard installed should have a set of engineer reviewed and stamped shop drawings and that site inspections should be made mandatory across the country.

©Annex Glass Canada. View All Articles.

You Bet Your Glass
https://magazine.glasscanadamag.com/articles/you-bet-your-glass?article_id=2703409&i=380994

Menu
  • Page View
  • Contents View
  • Advertisers
  • Website

Issue List

August 2025

June 2025

Top Glass Showguide 2025

March 2025

October 2024

August 2024

June 2024

Top Glass Showguide 2024

March 2024

October 2023

August 2023

June 2023

Top Glass Showguide 2023

March 2023

December 2022

October 2022

August 2022

June 2022

April 2022

February 2022

December 2021

October 2021

August 2021

June 2021

April 2021

February 2021

December 2020

October 2020

August 2020

June 2020

April 2020

February 2020

December 2019

October 2019

August 2019

June 2019

April 2019

February 2019

December 2018

October 2018

August 2018

June 2018

April 2018

February 2018

December 2017

October 2017

August 2017

June 2017

April 2017

February 2017

December 2016

October 2016

August 2016

June 2016

TopGlass-ShowReport-May16

April 2016

February 2016

December 2015

WINDOOR-DigitalWrap-2015

October 2015

August 2015

June 2015

Top Glass digital wrap up

April 2015

February 2015

December 2014

October 2014

August 2014

June 2014

April 2014

February 2014

December 2013

October 2013

August 2013

Top Glass, June 2013

June 2013

April 2013

February 2013

December 2012

October 2012

August 2012

June 2012

Directory 2012

May 2012

February 2012

December 2011

October 2011

August 2011

June 2011

April 2011

February 2011

December 2010

October 2010

July/August 2010

May/June 2010

March/April 2010

January/February 2010

December 2009

October 2009

August 2009

June 2009

April 09

Feb 2009

December 2008

October 08

August 2008

June 2008

April 2008


Library